Research System Stereomicroscope SZX16/SZX10 : Features (3)
- Dimension in image clarity
- Multi-wave length,astigmatism-free design for sharp 3D observation
- Exceptionally bright and even fluorescence
- Confortable operability
- Elgonomic
- Digital imaging
- Equipment answering various needs
- SZX10
The newly designed SDF objective lenses with high NA and Olympus' newly developed near-vertical reflected light illuminator will significantly improve signal intensity and support bright fluorescence observation.
Bright fluorescence observation is essential in recent biological and medical research. Observation of weak fluorescence at low magnification under a stereomicroscope has especially been a problem. However, the SZX16 enables even and overwhelmingly bright fluorescence observation from low to high magnifications.

Exceptionally high NA for extraordinarily bright fluorescence observation
The outstanding NA characteristics of SDF lenses dramatically improve fluorescence sensitivity. Furthermore, the newly designed near-vertical reflected light illuminator's excitation light paths are independent from the observation paths, allowing for substantially improved excitation light efficiency. These features provide far brighter fluorescence observation than conventional stereomicroscopes at all magnifications. Transmitted light observation for verification of specimen outline is possible even under reflected light fluorescence observation.
Even and seamless fluorescence observation from low to high magnification
In correspondence with zoom function, the reflected light fluorescence illuminator provides even illumination from low to high magnification. This will eliminate oversights along the periphery of the field of view during live specimen screening and dramatically improve work efficiency.

Five-position turret with nine-filter selection
Nine filter units, ranging from UV excitation to RFP, respond to applications using various fluorescent dyes and protein. Olympus High Quality (HQ) filters have an edge steepness and high transmission that efficiently detect the light of fluorescence to enhance and capture brighter fluorescence images in precise detail.

| Filter unit | Model | Remarks |
|---|---|---|
| For UV excitation | SZX2-FUV | Ex330-385/Em420- |
| For BV excitation | SZX2-FBV | Ex400-440/Em475- |
| High performance for CFP | SZX2-FCFPHQ | Ex425-445/Em460-510 |
| For GFP | SZX2-FGFP | Ex460-490/Em510- |
| For GFP separation | SZX2-FGFPA | Ex460-495/Em510-550 |
| High performance for GFP | SZX2-FGFPHQ | Ex460-480/Em495-540 |
| High performance for YFP | SZX2-FYFPHQ | Ex490-500/Em510-560 |
| For RFP 1 | SZX2-FRFP1 | Ex530-550/Em575- |
| For RFP 2 | SZX2-FRFP2 | Ex540-580/Em610- |